Associate Professor, International Institute of Earthquake Engineering and Seismology, Tehran, Iran
10.22034/jss.2009.237791
Abstract
This paper presents seismic behavior of several buildings with low torsional stiffness. The performance criterion is story drift ratio, as story drift ratio is an appropriate damage index for structural and non-structural elements comparably. Therefore, the safety of structure is defined by mentioned criterion. This study illustrates that the proposed provisions of standard 2800 of Iran for linear equivalent static analysis do not generally satisfy sufficient safety for low torsional stiffness structures. Therefore, linear equivalent static analysis in its present form is inadequate for low torsional stiffness structures.
Seyedtaghia,S. A. and Sarvghad Moghadam,A. (2009). Efficiency of Standard 2800 Provisions for Buildings with Low Torsional to Translational Modal Frequencies Ratio. Journal of Steel & Structure, 3(5), 40-51. doi: 10.22034/jss.2009.237791
MLA
Seyedtaghia,S. A. , and Sarvghad Moghadam,A. . "Efficiency of Standard 2800 Provisions for Buildings with Low Torsional to Translational Modal Frequencies Ratio", Journal of Steel & Structure, 3, 5, 2009, 40-51. doi: 10.22034/jss.2009.237791
HARVARD
Seyedtaghia S. A., Sarvghad Moghadam A. (2009). 'Efficiency of Standard 2800 Provisions for Buildings with Low Torsional to Translational Modal Frequencies Ratio', Journal of Steel & Structure, 3(5), pp. 40-51. doi: 10.22034/jss.2009.237791
CHICAGO
S. A. Seyedtaghia and A. Sarvghad Moghadam, "Efficiency of Standard 2800 Provisions for Buildings with Low Torsional to Translational Modal Frequencies Ratio," Journal of Steel & Structure, 3 5 (2009): 40-51, doi: 10.22034/jss.2009.237791
VANCOUVER
Seyedtaghia S. A., Sarvghad Moghadam A. Efficiency of Standard 2800 Provisions for Buildings with Low Torsional to Translational Modal Frequencies Ratio. Journal of Steel & Structure, 2009; 3(5): 40-51. doi: 10.22034/jss.2009.237791